Installation instructions from start to finish
1. Unpack
2. Measure
3. Cut to length
4. Fit
5. Staple
6. Finished
Interior ceiling
1 Ceiling between floors
2 Substructure
3 Air space
4 klimalan plus
5 Ceiling cladding
Interior wall
1 Interior cladding
2 Substructure
3 klimalan plus
4 Wall surface
Interior floor
1 Floor covering
2 klimalan plus
3 Timber substructure
4 klimalan filz
5 Screed
Installation level
1 External wall cladding
2 Battens/wood
3 Wind shield
4 thermalan iso
5 Structural timber
6 klimalan plus
7 Interior cladding
Interior roof insulation
1 Tiled roof
2 Battens/wood
3 Counter battens/wood
4 Fibreboard
5 klimalan plus
6 Structural timber
7 Recessed formwork
8 Interior cladding
Multifunctional fleece klimalan plus
Insulation made of pure new sheep’s wool mechanically strengthened with felt support
Applications
- Thermal insulation/Heat protection
- Sound insulation/Room acoustics
- Pollutant degradation - prevention/remediation
- Special applications - saunas
Installation options
- Acoustic ceilings
- Doubling existing insulation between structural timbers
- Installation level
- Partition and dry walls
- Between and under rafters
- Between structural timbers
- Ceilings and floors
- Interior insulation of outside walls
Composition
100% pure new sheep’s wool mechanically strengthened
- max. 0,2% lanolin (wool fat)
- 1% moth repellent relative to wool weight
- No synthetic support fibres
- No bonding agents
- No added flame retardants
Technical Data
•ETA ETA-09/0374
•Certification centre OIB
•Nominal value of heat conductivity (EN 12667) D(23/50) 0.035 W/m*K
•Fire performance (EN 13501-1) EURO-Class E
•Dimensional stability (EN 824) < 5 mm/m
•Thickness tolerance (EN 823) < -5%; < -5 mm
•Density range (EN 1602) 35-40 kg/m3
•Airflow resistance (EN 29053) 4.4 kPa*s/m2
•Water absorption (EN 1609) < 0.92 kg/m2
•Water vapour diffusion resistance = 1
•Specific heat capacity cp 1630 J/kg*k
•Fire index 5.3 (CH)
•Building material class B2 (D)